z/OS module messages - zDC system messages

ZDC000I

Full message

ZDC000I INITIALIZATION @@ FOR zDC @@ VER @@.@@.@@

Explanation

This informational message indicates that the initialization of the zDC has started or ended. The subsystem ID and the version of the product are displayed.

System action

Processing continues.

User response

None

ZDC001E

Full message

ZDC001E AN ERROR HAS OCCURRED DURING LOAD FOR MODULE @@

Explanation

At zDC system startup the was an attempt to load all the processing modules into storage. This load was unsuccessful for the module named (@@) in this message.

System action

zDC terminates.

User response

Ensure that the //STEPLIB or //JOBLIB DD statements in the JCL executing zDC point to the correct data sets and that these data sets contain the correct release of the zDC.

ZDC002E

Full message

ZDC002E MODULE=@@ R15=@@ R1=@@

Explanation

This message follows ZDC001 and gives the module name as well as the contents of R15 and R1 at the completion of the LPAD operation.

System action

zDC terminates.

User response

Save the information in this message if you need to contact your systems programmer or a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC003E

Full message

ZDC003E COMMON AREA STORAGE NOT AVAILABLE FOR MODULE @@

Explanation

This message indicates that the attempt to load the module named in the message into extended common storage has failed because there is not enough available storage to hold the module.

System action

zDC terminates.

User response

Increase the amount of common storage, specifically subpool 241, and start zDC again.

ZDC004E

Full message

ZDC004E AN ERROR HAS OCCURRED DURING BLDL FOR MODULE @@

Explanation

At zDC system startup there was an attempt to load all the processing modules into storage. The BLDL for this load was unsuccessful for the module named in the message.

System action

zDC terminates.

User response

Ensure that the //STEPLIB or //JOBLIB DD statements in the JCL executing zDC point to the correct data sets and that these data sets contain the correct release of the zDC.

ZDC005E

Full message

ZDC005E MODULE=@@ R15=@@ R1=@@

Explanation

This message follows ZDC004 and gives the module name, and the contents of R15 and R1 at the completion of the BLDL operation.

System action

zDC terminates.

User response

Save the information in this message if you have to contact your systems programmer or a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC006E

Full message

ZDC006E SUBSYSTEM @@ ALREADY EXISTS AND IS ACTIVE

Explanation

This message indicates that the 4-character subsystem ID you specified in the //SYSIN DD parameter data set already exists in your system and it is an active zDC subsystem.

System action

zDC terminates.

User response

Ensure that the subsystem ID you have specified is unique in your system. Then restart zDC or stop the instance of the zDC that holds this name.

ZDC007E

Full message

ZDC007E ECSA STORAGE NOT AVAILABLE FOR SUBSYSTEM @@, R15=@@

Explanation

This message indicates that the attempt to obtain storage for the subsystem control block has failed. There is not enough storage above the line in extended CSA sub-pool 241 for these blocks.

System action

zDC terminates.

User response

Increase the amount of extended CSA subpool 241 storage and restart the zDC.

ZDC008I

Full message

ZDC008I MODULE P/T DATE TIME VERSION ADDRESS LENGTH

Explanation

This message is displayed only at zDC startup. It names the columns shown below in multiple message numbers ZDC009. The module name, highest problem tracking number, the date and time the module was last assembled, the version of the module and the main storage address where it is loaded are shown.

System action

Processing continues.

User response

None

ZDC009I

Full message

ZDC009I @@ @@ @@ @@ @@ @@ @@

Explanation

This message lists one module loaded by zDC. See the ZDC008 message for a description of the columns.

System action

Processing continues.

User response

None

ZDC010E

Full message

ZDC010E SDUMPX TAKEN SUCCESSFULLY FOR zDC @@ ABEND

Explanation

This message is displayed on the system console by the zDC dump routines. It names the abend code.

System action

Execution terminates.

User response

Prepare the dump for examination by your systems staff or for transmission to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment. re-execute the zDC.

ZDC011E

Full message

ZDC011E SDUMPX FAILED FOR zDC @@ ABEND. RETCODE=@@/@@

Explanation

This message is displayed on the system console by the zDC dump routines. It indicates that the attempt to obtain a system dump has failed. The return and reason code for the failure are shown in the message.

System action

Execution terminates.

User response

Examine the return and reason codes or supply this message to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment. re-execute the zDC.

ZDC012E

Full message

ZDC012E @@ ABEND DUMP IN DYNATRACE zDC @@

Explanation

This message is the title for all SDUMPX macros issued by zDC. This title indicates the abend code that caused the dump to be taken.

System action

Execution terminates.

User response

Ensure that the dump is preserved and can be given to your systems programming staff or a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment. re-execute the zDC.

ZDC014E

Full message

ZDC014E ZDCLOGER VSAM @@ ERROR

Explanation

This message indicates that a non-zero return code has resulted from a VSAM zDC log request. The name of the request is contained in the message.

System action

The log task terminates but the execution of the zDC continues.

User response

Examine the subsequent messages, which contain detailed information about the nature of the error. Keep this information for your systems programming staff or for a Dynatrace product expert via live chat. Try to and re-attach and re-open the log (MVS command: Modify ZdcStcName,LOG OPEN).

Please contact a Dynatrace product expert via live chat within your environment.

ZDC015E

Full message

ZDC015E ZDCLOGER VSAM RPL FEEDBACK WORD @@

Explanation

This message contains the value of the VSAM RPL feedback word following a VSAM PUT to the log data set.

System action

The log task terminates but execution of the zDC continues.

User response

Examine the subsequent messages, which contain detailed information about the nature of the error. Keep this information for your systems programming staff or for a Dynatrace product expert via live chat. Try to re-attach and re-open the log (MVS command: Modify ZdcStcName,LOG OPEN).

Please contact a Dynatrace product expert via live chat within your environment.

ZDC016E

Full message

ZDC016E ZDCLOGER VSAM ACB ERROR FLAG @@

Explanation

This message contains the value of the VSAM ACB error flag following a VSAM OPEN or CLOSE of the log data set.

System action

The log task terminates but execution of the zDC continues.

User response

Examine the subsequent messages, which contain detailed information about the nature of the error. Keep this information for your systems programming staff or for a Dynatrace product expert via live chat. Enter the ISPF zDC control system. Then re-attach and re-open the log.

Please contact a Dynatrace product expert via live chat within your environment..

ZDC017E

Full message

ZDC017E SRB ABEND @@ AT DISPLACEMENT @@ INTO ZDCSRBRT

Explanation

This message indicates that an abend has occurred at the displacement shown into the SRB routine named ZDCSRBRT.

System action

Execution terminates.

User response

If a dump is produced, save it for your systems staff or for transmission to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment. re-execute the zDC.

ZDC018E

Full message

ZDC018E EXTENDED CSA STORAGE NOT AVAILABLE FOR SRB ROUTINE

Explanation

This message indicates that a STORAGE OBTAIN has failed to report that extended CSA storage from subpool 241 is not available.

System action

Execution terminates.

User response

Report this condition to your systems programmer who may want to increase the amount of extended CSA storage in the system.

ZDC019E

Full message

ZDC019E zDC INITIALIZATION FAILED. RETCODE=@@/@@

Explanation

This message indicates that the initialization routines have failed. It also shows the return and reason codes describing this failure.

System action

zDC execution terminates.

User response

Examine the SYSPRINT data set for any other messages that may be relevant to the failure.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC026I

Full message

ZDC026I STOP COMMAND ACCEPTED

Explanation

This message confirms that the STOP command entered by an operator has been accepted by zDC and end of job processing has commenced.

System action

Execution terminates.

User response

None

ZDC027I

Full message

ZDC027I MODIFY COMMAND RECEIVED

Explanation

This message confirms that the MODIFY command entered by an operator has been received by zDC and is processing. Any errors encountered during parsing or execution of the command are indicated later.

System action

Execution continues.

User response

None

ZDC028I

Full message

ZDC028I @@

Explanation

This message contains a copy of the entire command entered by the operator in the console. Only the first 120 bytes of the command are displayed.

System action

Execution continues.

User response

None

ZDC029E

Full message

ZDC029E TCPSP subtask unavailable to process shutdown request

Explanation

This message indicates that the ECB for TCPSP subtask is busy and unavailable to receive the shutdown request.

System action

Execution terminates.

User response

If a dump is produced, save it for your systems staff or for transmission to a Dynatrace product expert via live chat. Re-execute the zDC.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC033E

Full message

ZDC033E INVALID COMMAND. PLEASE REENTER

Explanation

The command you just entered in the operator console was invalid and wasn't processed.

System action

The command is ignored and processing continues.

User response

Re-enter a valid command if possible. If the command was valid, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC035I

Full message

ZDC035I @@ ARMED FOR AUTOMATIC RESTART

Explanation

This message indicates that you have selected ARM processing and this is the first time the element named in this message has been armed. This means the execution is not due to an automatic restart.

System action

Processing continues.

User response

None

ZDC036I

Full message

ZDC036I @@ RESTARTED DUE TO PREVIOUS ABEND. RSNCD=@@

Explanation

This message indicates that this zDC has been automatically restarted by the system. The reason code indicates whether the JCL or START command has been changed (RSNCD=108) or has not been changed (RSNCD=104).

System action

Processing continues.

User response

None

ZDC037E

Full message

ZDC037E @@ IXCARM REGISTER FAILURE. RETCD=@@. RSNCD=@@

Explanation

An attempt to issue IXCARM macro has resulted in a return code greater than 4. This indicates that the request did not complete. The actual return and reason codes are shown in this message.

System action

Processing continues but without ARM support.

User response

See the z/OS MVS Sysplex Services Reference for a complete list of the possible return and reason codes. Correct any environmental errors or report this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC038E

Full message

ZDC038E @@ IXCARM READY FAILURE. RETCD=@@. RSNCD=@@

Explanation

An attempt to issue IXCARM macro has resulted in a return code greater than 4. This indicates that the request did not complete. The actual return and reason codes are shown in this message.

System action

Processing continues but without ARM support.

User response

See the z/OS MVS Sysplex Services Reference for a complete list of the possible return and reason codes. Correct any environmental errors or report this problem to a Dynatrace product expert via live chat within your Dynatrace environment.

ZDC039I

Full message

ZDC039I @@ AUTOMATIC RESTART NOT SUPORTED ON THIS SYSTEM

Explanation

An attempt to issue IXCARM macro has resulted in a return code indicating that ARM support is not available on this system, or it may be available but stopped.

System action

Processing continues but without ARM support.

User response

See the z/OS MVS Sysplex Services Reference for a complete list of the possible return and reason codes. You might need to issue the operator command SETXCF START,POLICY,TYPE=ARM to activate ARM processing.

ZDC040I

Full message

ZDC040I @@ DEREGISTERED FOR AUTOMATIC RESTART

Explanation

This message indicates that an IXCARM has been issued in order for the server to go to a normal end of job.

System action

Processing continues.

User response

None

ZDC048I

Full message

ZDC048I THE FOLLOWING MODULES ARE LOADED INTO ECSA

Explanation

This message is printed in the SYSPRINT data set and indicates that all modules named next via ZDC009I messages were loaded into ECSA.

System action

Processing continues.

User response

None

ZDC049I

Full message

ZDC049I THE FOLLOWING MODULES ARE LOADED INTO PRIVATE STORAGE

Explanation

This message is printed in the SYSPRINT data set and indicates that all modules named next via ZDC009I messages were loaded into the private area of the zDC.

System action

Processing continues.

User response

None

ZDC052I

Full message

ZDC052I zDC IS RUNNING ON @@ RELEASE @@

Explanation

This informational message indicates the name and release level on which this zDC is running.

System action

Processing continues.

User response

None

ZDC053I

Full message

ZDC053I LPAR NAME @@ CVTSNAME @@

Explanation

This informational message indicates the name of the LPAR on which this zDC is running and the name of the operating system on which this zDC is running.

System action

Processing continues.

User response

None

ZDC054E

Full message

ZDC054E zDC ACTIVE SUBSYSTEM @@ ALREADY MARKED AS DEFAULT

Explanation

This message indicates that during the process of establishing a new zDC subsystem on this LPAR, a previous subsystem named in the message was already active and marked as the default subsystem.

System action

zDC execution ends.

User response

Only one zDC subsystem at a time can be marked as the default. Change the parameter specification of this zDC to indicate DEFAULT(NO) and re-execute the zDC.

You can also stop the zDC job with the named subsystem, which allows another subsystem to specify it as the default one. Note, that if the zDC instance with the subsystem named is unable to be cancelled or if it has been cancelled and its subsystem remains active, then you can specify DEFAULT(YES,FORCE). The existing subsystem is marked as not the default and the new one is marked as the default.

ZDC055I

Full message

ZDC055I LPAR CPU capacity MSUs per hour:@@. If z/VM guest, capacity:@@

Explanation

This informational message indicates the MSU capacity on which this zDC is running. If running as z/VM guest, shows guest MSU capacity.

System action

Processing continues.

User response

None

ZDC056I

Full message

ZDC056I LPAR General Processors:@@, ZIIPs:@@

Explanation

This informational message indicates the processors vailable to LPAR and how many of them are ZIIP speciality processors.

System action

Processing continues.

User response

None

ZDC057I

Full message

ZDC057I LPAR Facility Indicators in hexdump format:

Explanation

Facilities installed in the configuration. Hex dump of the area to assist issue diagnosis. See STORE FACILITY LIST EXTENDED (STFLE) instruction

System action

Processing continues.

User response

None

ZDC059I

Full message

ZDC059I zDC NOW EXECUTING UNDER USERID @@

Explanation

This message is written to SYSPRINT indicating that the user ID you specified in TCPIP_USERID is now in control of the main task of the zDC.

System action

Processing continues.

User response

None

ZDC060I

Full message

ZDC060I LOG @@ @@ SUCCESSFULLY

Explanation

This message is written to SYSPRINT indicating that the action you requested in a LOG command has been successfully executed.

System action

Processing continues.

User response

None

ZDC061E

Full message

ZDC061E INSUFFICIENT ACCESS TO LOG DATA SET. SEE JOBLOG

Explanation

This message is written to SYSPRINT indicating that the USERIDunder which zDC is running does not have the necessary security access to the log data set. This access must be ACCESS(ALTER) in order that the log data set can be created and/or extended and be available.

System action

Processing continues but without the log.

User response

Either grant the user ID under which zDC is running ACCESS(ALTER) to the log data set or supply a user ID that has this access level. Note that the log data set must be defined as a generic entity in order to pass the RACROUTE used in zDC.

ZDC062E

Full message

ZDC062E LOG TASK INITIALIZATION FAILURE RC=@@/@@

Explanation

This message is written to SYSPRINT indicating that the log subtask has failed to initialize.

System action

zDC processing continues but without the log.

User response

Scan the system console and the JES job log for messages relating to this problem. Look carefully for any system access (RACF, ACF/2, TOPSECRET) messages relating to the log data set.

ZDC064E

Full message

ZDC064E QUEUE TASK INITIALIZATION FAILURE

Explanation

This message is written to SYSPRINT indicating that the queue subtask has failed to initialize.

System action

zDC terminates.

User response

Please contact a Dynatrace product expert via live chat within your environment.

ZDC065I

Full message

ZDC065I zDC INITIALIZATION SUCCESSFUL. RETCODE=00/00 @@

Explanation

This message is written to SYSPRINT indicating that initialization of the zDC has been successful.

System action

Processing continues.

User response

None

ZDC066E

Full message

ZDC066E QUEUE TASK FAILURE RETCODE=@@/@@

Explanation

This message is written to SYSPRINT indicating that the queue subtask has failed. Return and reason codes are contained in this message.

System action

zDC terminates.

User response

If "QUEUE"=DtAgt, in the message, review the following:

  • The zDC task tries to connect to the zRemote. One of the first things it does is bootstrap the zLocal from the server using the zRemote. If the bootstrapping fails, meaning that the zLocal can't be loaded, the zDC task tries three times then issues a user abend. The fallback is that if this happens, the zDC tries to load the most recently bootstrapped zLocal. If it is the first time the zDC has been started in a new work area on the OMVS filesystem, and there is no previously downloaded zLocal, then this user abend is issued.
  • Check that the zRemote code module parameter in the zDC //SYSIN is correct. This needs to point to the zRemote instance, which needs to be up and running, and connected to a server, so that the zLocal bootstrapping can happen.
  • Review the zDC spool output for bootstrap messages.

If "QUEUE"=QUEUE, in the message, report this message to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC067E

Full message

ZDC067E LOG TASK FAILURE RETCODE=@@/@@

Explanation

This message is written to SYSPRINT indicating that the log subtask has failed. Return and reason codes are contained in this message.

System action

Processing continues but without the log.

User response

Scan the system console and the JES job log for messages relating to this problem. Look carefully for any system access (RACF, ACF/2, TOPSECRET) messages relating to the log data set.

ZDC069W

Full message

ZDC069W zDC QUEUE IS AT @@% OF CAPACITY

Explanation

This message indicates that the queue is filling. New internal events are not accepted once the queue reaches 100%. This message first displays when the queue reaches 75% and it re-displays at each 5% interval. When the queue drops below 75%, this message is no longer displayed. This message appears on the system console as well as in the SYSPRINT data set.

System action

Execution continues.

User response

Please contact a Dynatrace product expert via live chat within your environment.

ZDC071W

Full message

ZDC071W UNABLE TO CONSTRUCT SDUMPX SYMREC RETCODE=@@/@@

Explanation

This message indicates that the ZDCSDUMP module could not create a symptom record to be included in the SDUMP that it was about to write.

System action

The dump is created but without a symptom record.

User response

None

ZDC072W

Full message

ZDC072W WLM ENCLAVE CREATION FAILED. @@ @@/@@

Explanation

This message indicates that the process to create an WLM enclave has not been successful. The function name is shown in the message along with the return and reason codes from execution of this function. This is a warning message only because execution of the zDC continues. See below.

System action

zDC execution continues but all processing is performed in task mode and the enclave SRB is not dispatched. Hence there is no execution on any zIIP.

User response

Report this message to your systems programmer who might need to contact a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC073I

Full message

ZDC073I WLM ENCLAVE @@ CREATED SUCCESSFULLY

Explanation

This message indicates that the process to create an WLM enclave has been successful and zDC is a member of the enclave named in the message.

System action

Processing continues.

User response

None

ZDC074E

Full message

ZDC074E WLM ENCLAVE DELETION FAILED. @@ @@/@@

Explanation

This message indicates that the process to delete a WLM enclave has not been successful. The function name is shown in the message along with the return and reason codes from the execution of this function.

System action

zDC execution ends.

User response

Report this message to your systems programmer who might need to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC076E

Full message

ZDC076E WLM ENCLAVE SRB EXECUTION FAILED. RETCODE=@@

Explanation

This message indicates that the enclave SRB has failed to execute correctly. If the RETCODE in this message is 1C, then message ZDC077 is written next with the details concerning the failure.

System action

zDC execution ends.

User response

Report this message to your systems programmer who might need to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC077E

Full message

ZDC077E WLM ENCLAVE SRB REASON CODES=@@ @@ @@

Explanation

The three codes in this message correspond to the IEAMSCHD SYNCHCOMPADDR, SYNCHCODEADDR and SYNCHRSNADDR values.

System action

zDC execution ends.

User response

Report this message to your systems programmer who might need to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC078W

Full message

ZDC078W QUERT.STAWXXX UNEXPECTED @@ DISPATCH DELAY @@ @@ @@ @@

Explanation

This message is written to SYSPRINT indicating that the zDC appears to be getting insufficient processor service to handle messages in a timely fashion.

System action

Processing continues.

User response

There are 2 formats of the message followed by 4 hex words:

  • {QueRt.StaWDGp Unexpected GP dispatch delay}
  • {QueRt.StaWZSp Unexpected ZIIP dispatch delay}

GP is general processor delay, while ZIIP is IBM's Systems Integrated Information Processor.
The first 2 hex words are a 64bit number in STCK format with the sum of the unexpected delays.
(Convert to decimal and divide by 4096 to getmicro-seconds) The 3rd and 4th word are a count of unexpected delays and a count of how may times the delay has been evaluated. The average unexpected delay is the 64bit sum divided by the unexpected delay count.

For example: ZDC078W QueRt.StaWDGp Unexpected GP dispatch delay 00000000 F7E0822C 00000003 000019E2. xF7E0822C/x00000003=1.015sec/3=.338sec average unexpected delay base on x19E2/6,626 observations.

By default, he message will display at most once every 10 minutes. An unexpected delay defaults to .25 sec. That is, a task goes into a wait for 2 seconds and gets control back after over 2.25 seconds.

zDC parm: ZDCDISPATCHDELAYWARN(25) sets delay threshold in .01 second units e.g. 25=250 milli-sec.

zDC parm: ZDCDISPATCHDELAYRPTM(10) sets reporting interval in minutes.

Generally, use your performance tools to look for workflow delays in the 10 minute window before the warning message (for example, IBM's RMF monitor III). Also, check PARMLIB member IEAOPTxx parameter:
IIPHONORPRIORITY=NO.

NO can cause ZIIP eligible work to be delayed if GP processors are available.

ZDC079W

Full message

ZDC079W IEAVRLS ERROR, RETURN CODE @@

Explanation

This message indicates that and internal release function didn't complete properly.

System action

Processing continues.

User response

If the issue persists, save the information in this message and contact your systems programmer or a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC083E

Full message

ZDC083E SUBSYSTEM @@ ALREADY EXISTS BUT IS NOT A zDC SUBSYSTEM

Explanation

This message indicates that the 4-character subsystem ID you specified in the //SYSIN DD parameter data set already exists on your system but is used by some other program that is not Dynatrace zDC.

System action

zDC terminates.

User response

Ensure that the subsystem ID you have specified is unique on your system then restart zDC.

ZDC100I

Full message

ZDC100I SYSIN PARAMETER LISTING

Explanation

This message indicates that the //SYSIN parameters specified by the customer are listed next.

System action

Processing continues.

User response

None

ZDC101I

Full message

ZDC101I END OF SYSIN PARAMETER LISTING TRANBUF-Megabytes=@@

Explanation

This message indicates that the //SYSIN parameters specified by the customer have all been previously listed.

System action

Processing continues.

User response

None

ZDC102E

Full message

ZDC102E SYSTEM VARIABLE SUBSTITUTION FAILED. @@

Explanation

During the parsing of the //SYSIN DD data, the z/OS system variable substitution routine is called for each parameter. A non-zero return code resulted from one of these calls.

System action

zDC execution ends.

User response

Correct the parameter in error and re-execute the zDC.

ZDC103E

Full message

ZDC103E UNABLE TO OPEN //SYSIN DATA SET

Explanation

The attempt to open the SYSIN data set failed. There is no return code associated with this error but a message may be displayed in the job log that better explains the error.

System action

zDC execution ends.

User response

Ensure that the //SYSIN DD statement exists in the JCL used to invoke zDC and ensure that it points to a data set with DCB characteristics of LRECL=80.

ZDC105E

Full message

ZDC105E ILLOGICAL SEQUENCE OF COMMENT CONTROL CHARACTERS

Explanation

Comment control characters are "/" to begin a comment and "/" to end a comment. These must be paired; one of each. All statements between this pair are treated as a comment. This message indicates that the pairing of these control sequences is not correct.

System action

zDC execution ends.

User response

Correct the comment pairing error and re-execute the zDC.

ZDC106E

Full message

ZDC106E UNKNOWN SYSIN KEYWORD @@

Explanation

The SYSIN keyword shown in the message text is not one of the valid keywords.

System action

zDC execution ends.

User response

Correct the keyword in the SYSIN data set and re-execute the zDC.

ZDC107E

Full message

ZDC107E SUBSYSTEM_ID PARAMETER MISSING

Explanation

The SUBSYSTEM_ID parameter names a unique 4-character name for this zDC instance. This name must not be duplicated on this LPAR, and must NOT be defined in the SYS1.PARMLIB IEFSSNxx member.

System action

zDC execution ends.

User response

Add the SUBSYSTEM_ID parameter to the //SYSIN data set and re-execute the zDC. This 4-character name must be unique across all subsystems running on this LPAR but may be the same on different LPARs. You may name all your zDC subsystems with the same name on each LPA. But on any one LPAR this name must be unique. Do not define this name in the IEFSSNxx SYS1.PARMLIB member.

ZDC110E

Full message

ZDC110E NAME PARAMETER MISSING

Explanation

The NAME parameter is required and must specify a name for this zDC that is meaningful to personnel in your enterprise who may see messages from this zDC. The value you specify in the NAME parameter is not used for any purpose except to uniquely identify this instance of the zDC.

System action

zDC execution ends.

User response

Add the NAME parameter and re-execute the zDC.

ZDC116E

Full message

ZDC116E AUTOMATIC RESTART MANAGEMENT NAME MISSING

Explanation

You have specified ARM(YES) but have not specified the name to be used for Automatic Restart Management. This name must be from 1 to 16 bytes long. zDC registers with the z/OS automatic restart management and is then eligible for this facility. This name can consist of uppercase letters, numbers, and the following special characters: underscore (_), dollar sign ($), pound sign(#), or At sign (@). The first character cannot be numeric.

System action

zDC execution ends.

User response

See z/OS V1Rn.0 MVS Setting Up a Sysplex for a complete discussion of how an installation invokes this facility. When all of the steps outlined in this manual have been followed, then add the ARM_NAME parameter and re-execute the zDC. In the meantime, specify ARM(NO) or omit the parameter.

ZDC121E

Full message

ZDC121E SUBSYSTEM_ID PARAMETER INVALID

Explanation

The SUBSYSTEM_ID parameter has been specified but is not valid. The value for this parameter must be 4 bytes long consisting only of uppercase letters and numbers and dollar sign ($), pound sign(#), or At sign (@). The first character must be a letter.

System action

zDC execution ends.

User response

Correct the SUBSYSTEM_ID parameter and re-execute the zDC.

ZDC122E

Full message

ZDC122E DISPLAY_NAME PARAMETER INVALID

Explanation

The DISPLAY_NAME parameter has been specified, but is not valid. The value for this parameter must be from 1 to 40 bytes long. Any displayable characters are valid.

System action

zDC execution ends.

User response

Correct the DISPLAY_NAME parameter and re-execute the zDC.

ZDC123E

Full message

ZDC123E DEFAULT PARAMETER INVALID

Explanation

The DEFAULT parameter has been specified, but is not valid. Only two values are allowed: YES or NO. Only one zDC instance in a given LPAR may specify that it is the default; all others must specify NO.

System action

zDC execution ends.

User response

Correct the DEFAULT parameter and re-execute the zDC.

ZDC125E

Full message

ZDC125E EVENT_WAIT PARAMETER INVALID

Explanation

The EVENT_WAIT parameter can only specify YES or NO.

If this parameter is omitted YES is assumed. An EVENT_WAIT specified as YES or allowed to default to YES indicates that when events are processed, programs are kept from continuing their execution until the event has been successfully processed by the zDC address space. In most cases this is the desirable option. If it is determined that too much time is lost while zDC is processing the event, then specify NO to this parameter. The liability is that events may be lost if zDC terminates abnormally.

System action

zDC execution ends.

User response

Correct the EVENT_WAIT parameter and re-execute the zDC.

ZDC126E

Full message

ZDC126E TCPIP_USERID PARAMETER INVALID

Explanation

The TCPIP_USERID parameter must specify a 1- to 8-character valid user ID. You may omit this parameter in which case the user ID under which zDC was submitted is used.

System action

zDC execution ends.

User response

Either correct the user ID parameter or omit it entirely. re-execute the zDC.

ZDC127E

Full message

ZDC127E LOG_INITIAL PARAMETER INVALID

Explanation

The LOG_INITIAL parameter must specify either (OPEN) (CLOSED) or (). Any other values are invalid.

If you omit this parameter or specify () the default is LOG_INITIAL(CLOSED). Specify all the other parameters for logging that are applicable to your SMS environment, and also specify LOG_INITIAL(CLOSED). You can dynamically start logging using the specified parameters if the need arises. With the log in a CLOSED state no system resources are consumed.

System action

zDC execution ends.

User response

Correct the LOG_INITIAL parameter and re-execute the zDC.

ZDC128E

Full message

ZDC128E LOG_DSNAME PARAMETER IS INVALID

Explanation

The LOG_DSNAME parameter must specify a 1 to 35- character data set name for the optional logging. Be sure you haven't specified more than 35 characters because IDCAMS appends a .DATA and a .INDEX to this name when the cluster is defined.

System action

zDC execution ends.

User response

Correct the LOG_DSNAME and re-execute the zDC.

ZDC130E

Full message

ZDC130E LOG_VOLSER PARAMETER IS INVALID

Explanation

The LOG_VOLSER parameter must specify a 6-character volume serial number for the volume on which the log is to be defined. You must specify this parameter only if your SMS environment dictates it, else you may omit this parameter and take your system defaults.

System action

zDC execution ends.

User response

Correct the LOG_VOLSER and re-execute the zDC.

ZDC131E

Full message

ZDC131E LOG_TRKS PARAMETER IS INVALID

Explanation

The LOG_TRKS parameter must specify a 1 to 8-digit number representing the number of tracks you want defined in the primary and secondary extents of the log data set. The maximum value for this parameter is 65535 and the minimum value is 1.

System action

zDC execution ends.

User response

Correct the LOG_TRKS and re-execute the zDC.

ZDC132E

Full message

ZDC132E LOG_CYLS PARAMETER IS INVALID

Explanation

The LOG_CYLS parameter must specify a 1 to 8-digit number representing the number of cylinders you want defined in the primary and secondary extents of the log data set. The maximum value for this parameter is 65535 and the minimum value is 1.

System action

zDC execution ends.

User response

Correct the LOG_CYLS and re-execute the zDC.

ZDC133E

Full message

ZDC133E LOG_MGMTCLASS PARAMETER IS INVALID

Explanation

The LOG_MGMTCLASS parameter must specify a 1- to 8-character name for the management class SMS parameter that is defined in your installation for the log data set.

System action

zDC execution ends.

User response

Correct the LOG_MGMTCLASS parameter and re-execute the zDC.

ZDC134E

Full message

ZDC134E LOG_DATACLASS PARAMETER IS INVALID

Explanation

The LOG_DATACLASS parameter must specify a 1- to 8-character name for the data class SMS parameter that is defined in your installation for the log data set.

System action

zDC execution ends.

User response

Correct the LOG_DATACLASS parameter and re-execute the zDC.

ZDC135E

Full message

ZDC135E LOG_STORCLASS PARAMETER IS INVALID

Explanation

The LOG_STORCLASS parameter must specify a 1- to 8-character name for the storage class SMS parameter that is defined in your installation for the log data set.

System action

zDC execution ends.

User response

Correct the LOG_STORCLASS parameter and re-execute the zDC.

ZDC155E

Full message

ZDC155E ARM PARAMETER INVALID

Explanation

The ARM parameter must specify either ARM(YES), if you want Automatic Restart Management to restart this zDC in case of abnormal termination, or ARM(NO), if you do not want the zDC restarted. Initially you should specify ARM(NO) until you have assured yourself that the zDC is working correctly under normal circumstances. When this is the case you can request ARM support.

System action

zDC execution ends.

User response

Correct the ARM parameter and re-execute the zDC

ZDC156E

Full message

ZDC156E ARM_ELEMENT_NAME PARAMETER INVALID

Explanation

The ARM_ELEMENT_NAME parameter specifies a 1- to 16- character name to be used by z/OS in identifying this program to the Automatic Restart Management system.

Only letters and numbers and the special characters _, $, # and @ are valid. In addition, the first byte must not be numeric.

System action

zDC execution ends.

User response

Correct the ARM_ELEMENT_NAME parameter and re-execute the zDC.

ZDC185E

Full message

ZDC185E PROTECT PARAMETER INVALID

Explanation

The PROTECT parameter must specify PROTECT(YES) if pages in extended common storage are to be protected from inadvertent alteration by other programs running in the LPAR or PROTECT(NO) if this protection is not to occur. If this parameter is omitted then no protection exists. Any program running in key 0 can alter this storage.

System action

zDC execution ends.

User response

Correct the PROTECT parameter and re-execute the zDC.

ZDC187E

Full message

ZDC187E DEFAULT PARAMETER MISSING

Explanation

The DEFAULT parameter is required as either DEFAULT(YES) or DEFAULT(NO). Only one zDC subsystem in the LPAR can specify DEFAULT(YES). All others must specify DEFAULT(NO).

System action

zDC execution ends.

User response

Add the DEFAULT parameter and re-execute the zDC.

ZDC189E

Full message

ZDC189E OPERATING_SYSTEM PARAMETER INVALID

Explanation

The OPERATING_SYSTEM parameter should never be specified at a customer parameter. Its use is only for emulating releases of z/OS earlier than the current one.

System action

zDC ends.

User response

Remove this parameter from the SYSIN data set.

ZDC194E

Full message

ZDC194E zIIP_ENABLE PARAMETER INVALID

Explanation

The zIIP_ENABLE parameter can specify YES or NO. If zIIP_ENABLE(YES) is specified, then the SRB under which all XML creation and TCP/IP SOCKET(SEND) routines run is zIIP enabled. This SRB is not run on your zIIP if set to NO.

System action

zDC execution ends.

User response

Correct the zIIP_ENABLE parameter and resubmit zDC.

ZDC196E

Full message

ZDC196E DTMSG_QSIZE PARAMETER IS INVALID

Explanation

The DTMSG_QSIZE parameter specifies a Data Space size in Kilobyte. The default is 1024 (1024K). This Data Space is used to queue messages from the CICS code module of OneAgent to the zLocal. The minimum value is 8 and the maximum is 262144K (256Megabytes).

System action

zDC execution ends.

User response

Specify a value in the range given.

ZDC197E

Full message

ZDC197E DTMSG_SMOSIZE PARAMETER IS INVALID

Explanation

The DTMSG_SMOSIZE parameter specifies a 64-bit SMO size in MB. The default is 1 MB. This 64-bit SMO is used to queue messages from the CICS code module to the zLocal. The minimum value is 1 and the maximum is 256 MB. (256 Megabytes).

System action

zDC execution ends.

User response

Choose a correct value for SMOSIZE and then resubmit zDC.

ZDC198E

Full message

ZDC198E DT_UMASK PARAMETER IS INVALID

Explanation

The DT_UMASK parameter specifies user file-creation mask. The default is 0022(octal) and corresponds to rwxr-xr-x permission for new files. Error is generated if the parameter is over 3 characters, or contain non-octal characters (o:7).

System action

zDC execution ends.

User response

Choose a correct value for DT_UMASK and then resubmit zDC.

ZDC199E

Full message

ZDC199E DTMSG_TBCSIZE PARAMETER IS INVALID

Explanation

The DTMSG_TBCSIZE parameter specifies a 64-bit Transaction buffer total size in MB and either a 2K or 4K buffer size. The default is (1,2), which stands for 1MB and 2K buffer. This 64-bit SMO is used to buffer messages related to a transaction before being sent to OneAgent. The minimum value is 1 and the maximum is 256 MB (256Megabytes).

System action

zDC execution ends.

User response

Choose a correct value for TBCSIZE and then resubmit zDC.

ZDC200I

Full message

ZDC200I DTMSG_QSIZE PARAMETER IS DEPRECATED

Explanation

The DTMSG_QSIZE parameter specified DataSpace size in Kilobytes It is replace by DTMSG_SMOSIZE(Megabytes) The parameter has been converted to Megabytes and used to set the SMO size.

System action

zDC execution continues.

User response

Use DTMSG_SMOSIZE in the future.

ZDC201E

Full message

ZDC201E ZDCLOGBUFFERSIZE PARAMETER IS INVALID

Explanation

ZDCLOGBUFFERSIZE specifies a log buffer in kilobytes. It is a SMO memory are areas to buffer the zDC .log file. The zDC .log file in the same directory as the ZLocal code module .log files. The default is (64) - 64K. The minimum is 16K, the maximum is 10240K =10M.

System action

zDC execution ends.

User response

Correct value for ZDCLOGBUFFERSIZE and resubmit.

ZDC202E

Full message

ZDC202E ZDCMAXLOGFILESIZE PARAMETER IS INVALID

Explanation

ZDCMAXLOGFILESIZE specifies the log file size limit. It is used to rotate to a new log file when exceeded. The ZDClogfile pattern: .._ZDCID_PID_.#.log, for example: dt_DTV1ZDC4_MEPC_33620088.1.log. The default is (10240) =10M. The minimum is 10K; the maximum is 1048576K =1G.

System action

zDC execution ends.

User response

Correct value for ZDCMAXLOGFILESIZE and resubmit.

ZDC203E

Full message

ZDC203E ZDCDISPATCHDELAYWARN PARAMETER IS INVALID

Explanation

ZDCDISPATCHDELAYWARN specifies an unexpected dispatch delay threshold in units of .01sec. For example, ZDCDISPATCHDELAYWARN(100) specifies 1sec. The default is (25) =.25sec. The minimum non-zero valuse is 10 =.1sec. The maximum is (32000) =320sec. Disable delay checking: ZDCDISPATCHDELAYWARN(0)

System action

zDC execution ends.

User response

Correct value for ZDCDISPATCHDELAYWARN and resubmit.

ZDC204E

Full message

ZDC204E ZDCDISPATCHDELAYRPTM PARAMETER IS INVALID

Explanation

ZDCDISPATCHDELAYRPTM specifies a minimum report interval for unexpected dispatch delay in minutes. If no exceptions occur, no warning is reported.

For example, ZDCDISPATCHDELAYRPTM(15) reports delays at most every 15 minutes.

The default is (10) =10Minutes
The minimum is (1) (not recommended, small)
The maximum is (32000) (over 533Hours)

System action

zDC execution ends.

User response

Correct value for ZDCDISPATCHDELAYRPTM and resubmit.

ZDC205E

Full message

ZDC205E ZEDC_COMPRESS PARAMETER IS INVALID

Explanation

The ZEDC_COMPRESS parameter may specify a 1- or 2-digit number representing the minimum size for a data block to be eligible for zEDC hardware assisted data compression.

Smaller blocks will be sent without compression.

A null argument may be specified to enable hardware data compression using the 8K default minimum block size.

System action

zDC execution ends.

User response

Correct the ZEDC_COMPRESS parameter and re-execute the zDC.

ZDC206E

Full message

ZDC206E TCP_BUFFER PARAMETER IS INVALID

Explanation

The TCP_BUFFER parameter specifies a 1- to 4-digit number representing the size of the buffer that is used to pass OneAgent data to TCP/IP.

System action

zDC execution ends.

User response

Correct the TCP_BUFFER parameter and re-execute the zDC.

ZDC207E

Full message

ZDC207E ZEDC_COMPRESS MUST BE SMALLER THAN TCP_BUFFER

Explanation

The minimum compression threshold must be smaller than the size of the TCP/IP buffer.

System action

zDC execution ends.

User response

Correct one of the parameters and re-execute the zDC.

ZDC208I

Full message

ZDC208I METRIC_INTERVAL PARAMETER IS INVALID

Explanation

  • The minimum interval is 10 seconds.
  • The maximum interval is 600 seconds.

Specify a zero value to disable metrics processing.

System action

Processing continues.

User response

Correct the parameter and re-execute the zDC.

ZDC209I

Full message

ZDC209I DISPLAY_INTERVAL PARAMETER IS INVALID

Explanation

  • The minimum interval is 10 seconds.
  • The maximum interval is 600 (seconds).

Specify a zero value to disable AutoDisplay processing.

System action

Processing continues.

User response

Correct the parameter and re-execute the zDC.

ZDC210I

Full message

ZDC210I zDC NO LONGER LINKED TO TCP/IP

Explanation

This informational message indicates that the TERMAPI macro was successfully executed to terminate TCP/IP communications.

System action

Processing continues.

User response

None

ZDC211E

Full message

ZDC211E DTMSG_TRANBUFSIZE PARAMETER IS INVALID

Explanation

The DTMSG_TRANBUFSIZE parameter specifies a Transaction buffer total size in thousands of buffers and either a 2K or 4K buffer size. The default is (1,2), which stands for 1 thousand 2K buffers. This 64-bit SMO is used to buffer messages related to a transaction before being sent to the zLocal. The minimum value is (1,2), maximum is (126,4) or (248,2) (512Megabytes).

System action

zDC execution ends.

User response

Choose a correct value for DTMSG_TRANBUFSIZE and resubmit.

ZDC212E

Full message

ZDC212E zremoteagent= IS REQUIRED IN DTAGTCMD

Explanation

A zRemote code module parameter is required. The zRemote code module properties such as host and port are not specified in the DTAGTCMD parameter.

System action

zDC is terminated.

User response

Add zremoteagent= to DTAGTCMD resubmit zDC.

ZDC213W

Full message

ZDC213W TCP_BUFFER PARAMETER IS OUT OF RANGE, SETTING 8K or 256K

Explanation

The TCP_BUFFER parameter must be in range from 8k to 256k. If less than 8k is specified, 8k is used. If more than 256k is specified, 256k is used.

System action

Processing continues.

User response

Correct the TCP_BUFFER parameter for next ZDC execution.

ZDC215I

Full message

ZDC215I TERMINATION STARTED FOR zDC @@

Explanation

This informational message indicates that termination processing has started for this zDC.

System action

Termination processing continues.

User response

None

ZDC217I

Full message

ZDC217I LONG TERM STORAGE STATISTICS FOLLOW

Explanation

This informational message is followed by messages that show the number of bytes of storage allocated in each of the designated areas. These numbers may only be approximate as dynamic storage areas are not included in them.

System action

Processing continues.

User response

None

ZDC218I

Full message

ZDC218I PAGEABLE PRIVATE STORAGE @@

Explanation

The number of bytes of private zDC storage that is allocated long term is shown in this message. This number may only be approximate as dynamic storage areas are not included. Storage allocated both over and under the 16M line are included in this number.

System action

Processing continues.

User response

None

ZDC219I

Full message

ZDC219I PAGEABLE COMMON STORAGE - CSA: @@ ECSA: @@

Explanation

The number of bytes of subpool 241 (pageable common) storage that has been allocated for the duration of the zDC execution.

System action

Processing continues.

User response

None

ZDC220I

Full message

ZDC220I FIXED COMMON STORAGE - SQA: @@ ESQA: @@

Explanation

The number of bytes of subpool 245 (fixed common) storage that has been allocated for the duration of the zDC execution.

System action

Processing continues.

User response

None

ZDC221I

Full message

ZDC221I NUMBER SP 241 PAGES PROTECTED: @@

Explanation

The number of pages in subpool 241 that have had the PGSER PROTECT macro issued against them. This message displays only if you have specified PROTECT(YES) in the SYSIN parameter data set.

System action

Processing continues.

User response

None

ZDC302E

Full message

ZDC302E Message @@ - BAD REC ADDRESS PASSED

Explanation

Validation routines invoked to ensure that each message to the zLocal is valid has detected an error in the data.

System action

If logging is active, the event is logged. This message is written to the user's JOBLOG and the event is discarded.

User response

Please contact a Dynatrace product expert via live chat within your environment.

ZDC666W

Full message

ZDC666W List of possible zDC CPU contenders

Explanation

This informational message warns that the zDC might be contenting with other work for access to the processors. Up to 6 Job names are shown.

System action

Processing continues. Check with the system performance group about adjusting the zDC priority.

User response

None.

ZDC8XXW

Full message

ZDC8XXW INTERNAL MESSAGES FROM TCP MODULE ZDCTCPSP

Explanation

Generally, these are internal diagnostic messages issued when the DTLOGLEVEL 2 or less (fine). They may be requested by Dynatrace software support to diagnose an issue.

System action

Processing continues.

User response

None

ZDC950E

Full message

ZDC950E DT PARAMETER INVALID

Explanation

The parameters DTPIPEPATH, DTCHDIR, DTAGTCMD, or DTLOG are invalid. See comments in the supplied sample config member for a description of these parameters.

System action

zDC execution ends.

User response

Correct the parameter and re-execute the zDC.

ZDC951I

Full message

ZDC951I CICS property update too frequent, under 30sec., discarded

Explanation

There is a limit on how frequently the internal tables that contain CICS properties can be updated. The current limit is 30 seconds.

System action

Informational, processing continues.

User response

Re-apply the update later.

ZDC952W

Full message

ZDC952W zDC zLocal… {Buffer–Type} is at @@% of capacity

Explanation

This message indicates that the queue is filling and you should be aware that, if it reaches 100%, new messages won't be sent to the zLocal, possibly causing distribute trace corruption.

This message first displays when the queue reaches 70% and re-displays at five percent increments. When utilization drops below 70%, this message no longer displays. Note that this message appears on the system console as well as in the SYSPRINT data set.

System action

Execution continues.

User response

Monitor these messages carefully.

  • If the {Buffer–Type}; is Trans Buffer Que, consider increasing zDC parameter: DTMSG_TRANBUFSIZE().
  • If the {Buffer–Type}; is SMO Buffer Space, consider increasing zDC parameter: DTMSG_SMOSIZE().

ZDC953I

Full message

ZDC953I ZIIP_ENABLE requires zremoteagent=, ZIIP_ENABLE NO forced

Explanation

ZIIP enablement requires remote agent option.

System action

Informational, processing continues.

User response

ZIIP enablement requires both the zremoteagent= in the DTABGCMT command line and ZIIP_ENABLE(YES) in the zDC SYSIN parameters.

ZDC954W

Full message

ZDC954W DT PARAMETER SYSLOG INVALID

Explanation

Dynatrace parameter SYSLOG is invalid. Only CONNECTSTATUS or () to disable the option are allowed.

System action

Informational, processing continues.

User response

Remove the parameter or code allowed values.

ZDC955L

Full message

ZDC955L Dynatrace connection being processed ZDC-Job/ID: @@/@@

Explanation

zLocal code module has connected though the zRemote code module to the Dynatrace server.

System action

Informational, processing continues.

User response

None

ZDC956E

Full message

ZDC956E Dynatrace zLocal agent disconnected from Dynatrace Server ZDC-Job/ID:@@/@@

Explanation

zLocal code module has disconnected from the Dynatrace server.

System action

Informational, processing continues.

User response

If this is not planned, investigate the outage.

ZDC957I

Full message

ZDC957I Dynatrace Check Agent Mapping. Capture Events disabled for xxxx iAdk. Diag:xxxxxxxx

Explanation

Ignore if expected, otherwise check Settings > Server-side service monitoring > Deep monitoring > Troubleshooting.

System action

Informational, processing continues.

User response

None

ZDC958I

Full message

ZDC958I Dynatrace INIT completed, ZDC AgentId received ZDC-Job/ID:@@/@@

Explanation

ZDC has completed sending INIT msg and received an AgentId response.

System action

Informational, processing continues.

User response

None

ZDC959I

Full message

ZDC959I The ZDC could not locate the IP in the SMO

Explanation

ZDC could not find the V4 IP address in the SMO. Verify your zLocal is current.

System action

Informational, processing continues.

User response

Confirm zLocal verion is current.

ZDC974E

Full message

ZDC974E Unexpected failure checking agent executable, Abort

Explanation

This message is written to the SYSPRINT and Oper. Check that the agent file exists and is executable. See DTAGTCMD() parameter.

System action

Processing terminates.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC975E

Full message

ZDC975E zLocal attach failed, Abort

Explanation

This message is written to the SYSPRINT and Oper. Check that the DTAGTCMD parameter references an accessible and executable OneAgent.

System action

Processing terminates.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC976E

Full message

ZDC976E Unexpected failure during change directory, Abort

Explanation

This message is written to the SYSPRINT and Oper. Check that the zDC has read+write access to the DTCHDIR directory.

System action

Processing terminates.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC977E

Full message

ZDC977E Unexpected failure during z/OS Unix API, Abort

Explanation

This message is written to the SYSPRINT and Oper. Check that the user ID that is running the zDC is defined to the security product. The userid is either the normally assigned ID, or overriden by the TCPIP_USERID parameter.

System action

Processing terminates.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat within your Dynatrace environment.

ZDC978E

Full message

ZDC978E Failed ZDC.FML Name/Token operation, Abort

Explanation

This message is written to the SYSPRINT and Oper. The MVS Name/Token is used for internal processing. The operation failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC979E

Full message

ZDC979E Waiting for Que Data Space failed, Abort

Explanation

This message is written to the SYSPRINT and Oper. The Data Space used to pass messages to the ZDC has not initialized.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat within your Dynatrace environment.

ZDC980E

Full message

ZDC980E Waiting for OMVS failed, Abort

Explanation

This message is written to the SYSPRINT and Oper. The OMVS kernel is not ready.

System action

Processing terminates with a dump.

User response

Check why the OMVS address space is not operational. Restart OMVS or delay zDC startup until OMVS is ready.

ZDC981E

Full message

ZDC981E DtmD.FlagBad internal error, Abort

Explanation

This message is written to the SYSPRINT and Oper. A critical Data Space process has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC982E

Full message

ZDC982E DtmD.LenBad internal error, Abort

Explanation

This message is written to the SYSPRINT and Oper. A critical Data Space process has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC983E

Full message

ZDC983E Timer routine critical error, Abort

Explanation

This message is written to the SYSPRINT and Oper. A critical timer wait function has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC984E

Full message

ZDC984E Critical error in Wait routine, Abort

Explanation

This message is written to the SYSPRINT and Oper. A Unix wait to check zLocal status has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC985E

Full message

ZDC985E Poll for data failed, Abort

Explanation

This message is written to the SYSPRINT and Oper. A Unix poll for zLocal messages has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC986E

Full message

ZDC986E Unnamed pipe required, Abort

Explanation

This message is written to the SYSPRINT and Oper. A Unix unnamed pipe is needed for zLocal communication.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC987E

Full message

ZDC987E Internal error unknown ECB, Abort

Explanation

This message is written to the SYSPRINT and Oper. A critial internal call function has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC988E

Full message

ZDC988E Unexpected PC return, Abort

Explanation

This message is written to the SYSPRINT and Oper. A critial internal call function has failed.

System action

Processing terminates with a dump.

User response

Check job log for additional error messages, correct them if possible. If still unresolved, refer this problem to a Dynatrace product expert via live chat.

Please contact a Dynatrace product expert via live chat within your environment.

ZDC989E

Full message

ZDC989E *Dbg*Developer build test message

Explanation

This message is written to the SYSPRINT and Oper. It is intended for internal diagnostic for Dynatrace loglevel:finer(1).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC990I

Full message

ZDC990I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal diagnostic for loglevel:finest(0).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC991I

Full message

ZDC991I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:finer(1).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC992I

Full message

ZDC992I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:fine(2).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC993I

Full message

ZDC993I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:config(3).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC994I

Full message

ZDC994I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:info(4)

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC995W

Full message

ZDC995W Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:warn(5).

System action

Informational, processing continues.

User response

If a connection issue, investigate the status of the zRemote code module. Otherwise, informational, processing continues.

ZDC996E

Full message

ZDC996E Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:severe(6).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC997I

Full message

ZDC997I Internal DynaDiag

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:debug(7).

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC998I

Full message

ZDC998I @@ @@ @@ @@

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace. Dynatrace product experts might ask that system parameters be changed to cause these messages.

System action

Informational, processing continues.

User response

Informational, processing continues.

ZDC999I

Full message

ZDC999I Internal DynaDiag: @@ @@ @@ @@

Explanation

This message is written to the SYSPRINT. It is intended for internal Dynatrace diagnostic and shouldn't appear under normal operation. Dynatrace product experts might ask that system parameters be changed to cause these messages.

System action

Informational, processing continues.

User response

Informational, processing continues.