@@) in this message.//STEPLIB or //JOBLIB DD statements in the JCL executing zDC point to the correct data sets and that these data sets contain the correct release of the zDC.ZDC001 and gives the module name as well as the contents of R15 and R1 at the completion of the LPAD operation.BLDL for this load was unsuccessful for the module named in the message.//STEPLIB or //JOBLIB DD statements in the JCL executing zDC point to the correct data sets and that these data sets contain the correct release of the zDC.ZDC004 and gives the module name, and the contents of R15 and R1 at the completion of the BLDL operation.//SYSIN DD parameter data set already exists in your system and it is an active zDC subsystem.ZDC009. The module name, highest problem tracking number, the date and time the module was last assembled, the version of the module and the main storage address where it is loaded are shown.ZDC008 message for a description of the columns.Modify ZdcStcName,LOG OPEN). Please contact a Dynatrace product expert via live chat within your environment.Modify ZdcStcName,LOG OPEN). Please contact a Dynatrace product expert via live chat within your environment.ZDCSRBRT.STORAGE OBTAIN has failed to report that extended CSA storage from subpool 241 is not available.IXCARM macro has resulted in a return code greater than 4. This indicates that the request did not complete. The actual return and reason codes are shown in this message.SETXCF START,POLICY,TYPE=ARM to activate ARM processing.IXCARM has been issued in order for the server to go to a normal end of job.SYSPRINT data set and indicates that all modules named next via ZDC009I messages were loaded into ECSA.SYSPRINT data set and indicates that all modules named next via ZDC009I messages were loaded into the private area of the zDC.DEFAULT(NO) and re-execute the zDC. You can also stop the zDC job with the named subsystem, which allows another subsystem to specify it as the default one. Note, that if the zDC instance with the subsystem named is unable to be cancelled or if it has been cancelled and its subsystem remains active, then you can specify DEFAULT(YES,FORCE). The existing subsystem is marked as not the default and the new one is marked as the default.TCPIP_USERID is now in control of the main task of the zDC.SYSPRINT indicating that the action you requested in a LOG command has been successfully executed.SYSPRINT indicating that the USERIDunder which zDC is running does not have the necessary security access to the log data set. This access must be ACCESS(ALTER) in order that the log data set can be created and/or extended and be available.SYSPRINT indicating that the log subtask has failed to initialize.(RACF, ACF/2, TOPSECRET) messages relating to the log data set.SYSPRINT indicating that the queue subtask has failed to initialize.SYSPRINT indicating that the queue subtask has failed. Return and reason codes are contained in this message."QUEUE"=DtAgt, in the message, review the following: * The zDC task tries to connect to the zRemote. One of the first things it does is bootstrap the zLocal from the server using the zRemote. If the bootstrapping fails, meaning that the zLocal can't be loaded, the zDC task tries three times then issues a user abend. The fallback is that if this happens, the zDC tries to load the most recently bootstrapped zLocal. If it is the first time the zDC has been started in a new work area on the OMVS filesystem, and there is no previously downloaded zLocal, then this user abend is issued. * Check that the zRemote code module parameter in the zDC //SYSIN is correct. This needs to point to the zRemote instance, which needs to be up and running, and connected to a server, so that the zLocal bootstrapping can happen. * Review the zDC spool output for bootstrap messages. If "QUEUE"=QUEUE, in the message, report this message to a Dynatrace product expert via live chat. Please contact a Dynatrace product expert via live chat within your environment.SYSPRINT indicating that the log subtask has failed. Return and reason codes are contained in this message.(RACF, ACF/2, TOPSECRET) messages relating to the log data set.ZDCSDUMP module could not create a symptom record to be included in the SDUMP that it was about to write.1C, then message ZDC077 is written next with the details concerning the failure.IEAMSCHD SYNCHCOMPADDR, SYNCHCODEADDR and SYNCHRSNADDR values.SYSPRINT indicating that the zDC appears to be getting insufficient processor service to handle messages in a timely fashion.ZDC078W QueRt.StaWDGp Unexpected GP dispatch delay 00000000 F7E0822C 00000003 000019E2. xF7E0822C/x00000003=1.015sec/3=.338sec average unexpected delay base on x19E2/6,626 observations. By default, he message will display at most once every 10 minutes. An unexpected delay defaults to .25 sec. That is, a task goes into a wait for 2 seconds and gets control back after over 2.25 seconds. zDC parm: ZDCDISPATCHDELAYWARN(25) sets delay threshold in .01 second units e.g. 25=250 milli-sec. zDC parm: ZDCDISPATCHDELAYRPTM(10) sets reporting interval in minutes. Generally, use your performance tools to look for workflow delays in the 10 minute window before the warning message (for example, IBM's RMF monitor III). Also, check PARMLIB member IEAOPTxx parameter: IIPHONORPRIORITY=NO. NO can cause ZIIP eligible work to be delayed if GP processors are available.//SYSIN DD parameter data set already exists on your system but is used by some other program that is not Dynatrace zDC.//SYSIN parameters specified by the customer are listed next.//SYSIN parameters specified by the customer have all been previously listed.//SYSIN DD data, the z/OS system variable substitution routine is called for each parameter. A non-zero return code resulted from one of these calls.SYSIN data set failed. There is no return code associated with this error but a message may be displayed in the job log that better explains the error.//SYSIN DD statement exists in the JCL used to invoke zDC and ensure that it points to a data set with DCB characteristics of LRECL=80.SYSIN keyword shown in the message text is not one of the valid keywords.SYSIN data set and re-execute the zDC.SUBSYSTEM_ID parameter names a unique 4-character name for this zDC instance. This name must not be duplicated on this LPAR, and must NOT be defined in the SYS1.PARMLIB IEFSSNxx member.//SYSIN data set and re-execute the zDC. This 4-character name must be unique across all subsystems running on this LPAR but may be the same on different LPARs. You may name all your zDC subsystems with the same name on each LPA. But on any one LPAR this name must be unique. Do not define this name in the IEFSSNxx SYS1.PARMLIB member.NAME parameter is required and must specify a name for this zDC that is meaningful to personnel in your enterprise who may see messages from this zDC. The value you specify in the NAME parameter is not used for any purpose except to uniquely identify this instance of the zDC.NAME parameter and re-execute the zDC.ARM(YES) but have not specified the name to be used for Automatic Restart Management. This name must be from 1 to 16 bytes long. zDC registers with the z/OS automatic restart management and is then eligible for this facility. This name can consist of uppercase letters, numbers, and the following special characters: underscore (_), dollar sign ($), pound sign(#), or At sign (@). The first character cannot be numeric.ARM_NAME parameter and re-execute the zDC. In the meantime, specify ARM(NO) or omit the parameter.$), pound sign(#), or At sign (@). The first character must be a letter.SUBSYSTEM_ID parameter and re-execute the zDC.DISPLAY_NAME parameter has been specified, but is not valid. The value for this parameter must be from 1 to 40 bytes long. Any displayable characters are valid.DISPLAY_NAME parameter and re-execute the zDC.DEFAULT parameter has been specified, but is not valid. Only two values are allowed: YES or NO. Only one zDC instance in a given LPAR may specify that it is the default; all others must specify NO.DEFAULT parameter and re-execute the zDC.YES or NO. If this parameter is omitted YES is assumed. An EVENT_WAIT specified as YES or allowed to default to YES indicates that when events are processed, programs are kept from continuing their execution until the event has been successfully processed by the zDC address space. In most cases this is the desirable option. If it is determined that too much time is lost while zDC is processing the event, then specify NO to this parameter. The liability is that events may be lost if zDC terminates abnormally.EVENT_WAIT parameter and re-execute the zDC.TCPIP_USERID parameter must specify a 1- to 8-character valid user ID. You may omit this parameter in which case the user ID under which zDC was submitted is used.LOG_INITIAL parameter must specify either (OPEN) (CLOSED) or (). Any other values are invalid. If you omit this parameter or specify (), the default isLOG_INITIAL(CLOSED). Specify all the other parameters for logging that are applicable to your SMS environment, and also specify LOG_INITIAL(CLOSED). You can dynamically start logging using the specified parameters if the need arises. With the log in a CLOSED state no system resources are consumed.LOG_INITIAL parameter and re-execute the zDC.LOG_DSNAME parameter must specify a 1 to 35- character data set name for the optional logging. Be sure you haven't specified more than 35 characters because IDCAMS appends a .DATA and a .INDEX to this name when the cluster is defined.LOG_DSNAME and re-execute the zDC.LOG_VOLSER parameter must specify a 6-character volume serial number for the volume on which the log is to be defined. You must specify this parameter only if your SMS environment dictates it, else you may omit this parameter and take your system defaults.LOG_VOLSER and re-execute the zDC.LOG_TRKS parameter must specify a 1 to 8-digit number representing the number of tracks you want defined in the primary and secondary extents of the log data set. The maximum value for this parameter is 65535 and the minimum value is 1.LOG_TRKS and re-execute the zDC.LOG_CYLS parameter must specify a 1 to 8-digit number representing the number of cylinders you want defined in the primary and secondary extents of the log data set. The maximum value for this parameter is 65535 and the minimum value is 1.LOG_CYLS and re-execute the zDC.LOG_MGMTCLASS parameter must specify a 1- to 8-character name for the management class SMS parameter that is defined in your installation for the log data set.LOG_MGMTCLASS parameter and re-execute the zDC.LOG_DATACLASS parameter must specify a 1- to 8-character name for the data class SMS parameter that is defined in your installation for the log data set.LOG_STORCLASS parameter must specify a 1- to 8-character name for the storage class SMS parameter that is defined in your installation for the log data set.LOG_STORCLASS parameter and re-execute the zDC.ARM parameter must specify either ARM(YES), if you want Automatic Restart Management to restart this zDC in case of abnormal termination, or ARM(NO), if you do not want the zDC restarted. Initially you should specify ARM(NO) until you have assured yourself that the zDC is working correctly under normal circumstances. When this is the case you can request ARM support.ARM parameter and re-execute the zDCARM_ELEMENT_NAME parameter specifies a 1- to 16- character name to be used by z/OS in identifying this program to the Automatic Restart Management system. Only letters and numbers and the special characters _, $, # and @ are valid. In addition, the first byte must not be numeric.ARM_ELEMENT_NAME parameter and re-execute the zDC.PROTECT parameter must specify PROTECT(YES) if pages in extended common storage are to be protected from inadvertent alteration by other programs running in the LPAR or PROTECT(NO) if this protection is not to occur. If this parameter is omitted then no protection exists. Any program running in key 0 can alter this storage.PROTECT parameter and re-execute the zDC.DEFAULT parameter is required as either DEFAULT(YES) or DEFAULT(NO). Only one zDC subsystem in the LPAR can specify DEFAULT(YES). All others must specify DEFAULT(NO).DEFAULT parameter and re-execute the zDC.OPERATING_SYSTEM parameter should never be specified at a customer parameter. Its use is only for emulating releases of z/OS earlier than the current one.SYSIN data set.zIIP_ENABLE parameter can specify YES or NO. If zIIP_ENABLE(YES) is specified, then the SRB under which all XML creation and TCP/IP SOCKET(SEND) routines run is zIIP enabled. This SRB is not run on your zIIP if set to NO.zIIP_ENABLE parameter and resubmit zDC.DTMSG_QSIZE parameter specifies a Data Space size in Kilobyte. The default is 1024 (1024K). This Data Space is used to queue messages from the CICS code module of OneAgent to the zLocal. The minimum value is 8 and the maximum is 262144K (256Megabytes).DTMSG_SMOSIZE parameter specifies a 64-bit SMO size in MB. The default is 1 MB. This 64-bit SMO is used to queue messages from the CICS code module to the zLocal. The minimum value is 1 and the maximum is 256 MB. (256 Megabytes).SMOSIZE and then resubmit zDC.DT_UMASK parameter specifies user file-creation mask. The default is 0022(octal) and corresponds to rwxr-xr-x permission for new files. Error is generated if the parameter is over 3 characters, or contain non-octal characters (o:7).DT_UMASK and then resubmit zDC.DTMSG_TBCSIZE parameter specifies a 64-bit Transaction buffer total size in MB and either a 2K or 4K buffer size. The default is (1,2), which stands for 1MB and 2K buffer. This 64-bit SMO is used to buffer messages related to a transaction before being sent to OneAgent. The minimum value is 1 and the maximum is 256 MB (256Megabytes).TBCSIZE and then resubmit zDC.DTMSG_QSIZE parameter specified DataSpace size in Kilobytes It is replace by DTMSG_SMOSIZE(Megabytes) The parameter has been converted to Megabytes and used to set the SMO size.DTMSG_SMOSIZE in the future.ZDCLOGBUFFERSIZE specifies a log buffer in kilobytes. It is a SMO memory are areas to buffer the zDC .log file. The zDC .log file in the same directory as the ZLocal code module .log files. The default is (64) - 64K. The minimum is 16K, the maximum is 10240K =10M.ZDCLOGBUFFERSIZE and resubmit.ZDCMAXLOGFILESIZE specifies the log file size limit. It is used to rotate to a new log file when exceeded. The ZDClogfile pattern: .._ZDCID_PID_.#.log, for example: dt_DTV1ZDC4_MEPC_33620088.1.log. The default is (10240) =10M. The minimum is 10K; the maximum is 1048576K =1G.ZDCMAXLOGFILESIZE and resubmit.ZDCDISPATCHDELAYWARN specifies an unexpected dispatch delay threshold in units of .01sec. For example, ZDCDISPATCHDELAYWARN(100) specifies 1sec. The default is (25) =.25sec. The minimum non-zero valuse is 10 =.1sec. The maximum is (32000) =320sec. Disable delay checking: ZDCDISPATCHDELAYWARN(0)ZDCDISPATCHDELAYWARN and resubmit.ZDCDISPATCHDELAYRPTM specifies a minimum report interval for unexpected dispatch delay in minutes. If no exceptions occur, no warning is reported. For example, ZDCDISPATCHDELAYRPTM(15) reports delays at most every 15 minutes. The default is (10) =10Minutes The minimum is (1) (not recommended, small) The maximum is (32000) (over 533Hours)ZDCDISPATCHDELAYRPTM and resubmit.ZEDC_COMPRESS parameter may specify a 1- or 2-digit number representing the minimum size for a data block to be eligible for zEDC hardware assisted data compression. Smaller blocks will be sent without compression. A null argument may be specified to enable hardware data compression using the 8K default minimum block size.TCP_BUFFER parameter specifies a 1- to 4-digit number representing the size of the buffer that is used to pass OneAgent data to TCP/IP.TCP_BUFFER parameter and re-execute the zDC.DTMSG_TRANBUFSIZE parameter specifies a Transaction buffer total size in thousands of buffers and either a 2K or 4K buffer size. The default is (1,2), which stands for 1 thousand 2K buffers. This 64-bit SMO is used to buffer messages related to a transaction before being sent to the zLocal. The minimum value is (1,2), maximum is (126,4) or (248,2) (512Megabytes).DTMSG_TRANBUFSIZE and resubmit.DTAGTCMD parameter.zremote= to DTAGTCMD resubmit zDC.PROTECT(YES) in the SYSIN parameter data set.DTLOGLEVEL 2 or less (fine). They may be requested by Dynatrace software support to diagnose an issue.DTPIPEPATH, DTCHDIR, DTAGTCMD, or DTLOG are invalid. See comments in the supplied sample config member for a description of these parameters.SYSPRINT data set.Trans Buffer Que, consider increasing zDC parameter: DTMSG_TRANBUFSIZE(). * If the {Buffer–Type}; is SMO Buffer Space, consider increasing zDC parameter: DTMSG_SMOSIZE().SYSLOG is invalid. Only CONNECTSTATUS or () to disable the option are allowed.SYSPRINT and Oper. Check that the agent file exists and is executable. See DTAGTCMD() parameter.SYSPRINT and Oper. Check that the zDC has read+write access to the DTCHDIR directory.SYSPRINT and Oper. Check that the user ID that is running the zDC is defined to the security product. The userid is either the normally assigned ID, or overriden by the TCPIP_USERID parameter.SYSPRINT and Oper. The MVS Name/Token is used for internal processing. The operation failed.SYSPRINT and Oper. The Data Space used to pass messages to the ZDC has not initialized.SYSPRINT and Oper. The OMVS kernel is not ready.SYSPRINT and Oper. A critical Data Space process has failed.SYSPRINT and Oper. A critical Data Space process has failed.SYSPRINT and Oper. A critical timer wait function has failed.SYSPRINT and Oper. A Unix wait to check zLocal status has failed.SYSPRINT and Oper. A Unix poll for zLocal messages has failed.SYSPRINT and Oper. A Unix unnamed pipe is needed for zLocal communication.SYSPRINT and Oper. A critial internal call function has failed.SYSPRINT and Oper. A critial internal call function has failed.SYSPRINT and Oper. It is intended for internal diagnostic for Dynatrace loglevel:finer(1).SYSPRINT. It is intended for internal diagnostic for loglevel:finest(0).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:finer(1).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:fine(2).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:config(3).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:info(4)SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:warn(5).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:severe(6).SYSPRINT. It is intended for internal Dynatrace diagnostic for Dynatrace loglevel:debug(7).SYSPRINT. It is intended for internal Dynatrace. Dynatrace product experts might ask that system parameters be changed to cause these messages.SYSPRINT. It is intended for internal Dynatrace diagnostic and shouldn't appear under normal operation. Dynatrace product experts might ask that system parameters be changed to cause these messages.